高級豪華插管頭,具有口腔和鼻插管、斷牙、舌水腫、喉痙攣、環甲膜切開術、可活動眼瞼,以及採用薄材料的矽膠頭部皮膚,當頭部放置在頭部時,能夠讓嘴巴自然張開插管時的嗅聞位置。 ET 管插入支援 E.T.、E.O.A.、P.T.L、L.M.A.、E.G.T.A.、iGel、O.P.A.、N.P.A. Combitube®、King System 插入和 BVM。
CNS head with cholinesterase inhibitor toxicity signs: light reactive eyes that can be set to 3 sizes and/or nonreactive conditions, tears, nasal mucus, foaming mouth, ETCO2 discharge, and prerecorded voice and vomiting sounds.
Wireless microphone for instructor dialog
Optional 16-channel wireless microphone to eliminate signal interference when using more than one SMART STAT
Lips and fingernails with cyanosis and CO flushing
Pericardiocentesis
Bilateral B/P and IV arms
FAST 1™ I/O access in the manubrium
External jugular catheterization
5-lead ECG monitoring and defibrillation
Urinary catheterization (Foley functional) with interchangeable genitalia
Abdominal sounds in 4 quadrants
Fluids onboard, including IV blood and urine output
Each pulse point can be shut down to emulate vascular difficulties or disease states
Lower left leg battery‚ up to 3 hours of operation per charge (extra battery legs are
Additional Features
On-board air compressor with no external connections
Advanced Deluxe Intubation Head with oral and nasal intubation, break-out teeth, tongue edema, laryngospasm, cricothyrotomy, moveable eyelids, and the silicone head skin that utilizes a thin material capable of allowing the mouth to open naturally when the head is placed in the sniffing position for intubation. ET tube insertion that supports E.T., E.O.A., P.T.L, L.M.A., E.G.T.A., iGel, O.P.A., N.P.A. Combitube®, King System insertion, and BVM.
Heart and lung sounds: 6 anterior and 4 posterior lung sound speakers and 4 heart sound speakers allowing for sounds to be heard in appropriate places. Stridor is only heard in the upper lung speakers, wheezes bases is only heard in the four lower lung speakers, etc.
12 always-active pulse points, in pairs, carotid, femoral, popliteal, pedal (dorsal arch), brachial, and radial
Distal pulses drop off with B/P set below 70 mmHg systolic
B/P settings of systolic and diastolic values with individual settings for the amplitude of the speaker sounds and to obtain an auscultatory gap
IM/SubQ injection sites bilaterally in deltoid and on right thigh
Bilateral chest complications of tension pneumothorax and chest tube insertion no damage is done to the manikin and reuse is immediately available (replacement skins included)
高級豪華插管頭,具有口腔和鼻插管、斷牙、舌水腫、喉痙攣、環甲膜切開術、可活動眼瞼,以及採用薄材料的矽膠頭部皮膚,當頭部放置在頭部時,能夠讓嘴巴自然張開插管時的嗅聞位置。 ET 管插入支援 E.T.、E.O.A.、P.T.L、L.M.A.、E.G.T.A.、iGel、O.P.A.、N.P.A. Combitube®、King System 插入和 BVM。
CNS head with cholinesterase inhibitor toxicity signs: light reactive eyes that can be set to 3 sizes and/or nonreactive conditions, tears, nasal mucus, foaming mouth, ETCO2 discharge, and prerecorded voice and vomiting sounds.
Wireless microphone for instructor dialog
Optional 16-channel wireless microphone to eliminate signal interference when using more than one SMART STAT
Lips and fingernails with cyanosis and CO flushing
Pericardiocentesis
Bilateral B/P and IV arms
FAST 1™ I/O access in the manubrium
External jugular catheterization
5-lead ECG monitoring and defibrillation
Urinary catheterization (Foley functional) with interchangeable genitalia
Abdominal sounds in 4 quadrants
Fluids onboard, including IV blood and urine output
Each pulse point can be shut down to emulate vascular difficulties or disease states
Lower left leg battery‚ up to 3 hours of operation per charge (extra battery legs are
Additional Features
On-board air compressor with no external connections
Advanced Deluxe Intubation Head with oral and nasal intubation, break-out teeth, tongue edema, laryngospasm, cricothyrotomy, moveable eyelids, and the silicone head skin that utilizes a thin material capable of allowing the mouth to open naturally when the head is placed in the sniffing position for intubation. ET tube insertion that supports E.T., E.O.A., P.T.L, L.M.A., E.G.T.A., iGel, O.P.A., N.P.A. Combitube®, King System insertion, and BVM.
Heart and lung sounds: 6 anterior and 4 posterior lung sound speakers and 4 heart sound speakers allowing for sounds to be heard in appropriate places. Stridor is only heard in the upper lung speakers, wheezes bases is only heard in the four lower lung speakers, etc.
12 always-active pulse points, in pairs, carotid, femoral, popliteal, pedal (dorsal arch), brachial, and radial
Distal pulses drop off with B/P set below 70 mmHg systolic
B/P settings of systolic and diastolic values with individual settings for the amplitude of the speaker sounds and to obtain an auscultatory gap
IM/SubQ injection sites bilaterally in deltoid and on right thigh
Bilateral chest complications of tension pneumothorax and chest tube insertion no damage is done to the manikin and reuse is immediately available (replacement skins included)
用於 STAT 模擬器的 Xtreme 創傷出血臂這些圖形爆炸傷提供了詳細的增強功能,挑戰任何從業者的護理水平。這些印痕的特徵是肌肉和骨骼缺失、肌肉撕脫、脂肪組織和骨端。 SMART STAT 模擬器的血液供應管線快速連接至印跡,且沒有血液飛濺,並對血流加壓,形成凌亂的傷口。正確使用止血帶會阻止血流。 Xtreme Bleeding Moulages 可與患者模擬器的 STAT 系列一起使用...
用於 STAT 模擬器的 Xtreme 創傷流血腿這些圖形爆炸傷口提供了詳細的增強功能,挑戰任何從業者的護理水平。這些印痕的特徵是肌肉和骨骼缺失、肌肉撕脫、脂肪組織和骨端。 SMART STAT 模擬器的血液供應管線快速連接至印跡,且沒有血液飛濺,並對血流加壓,形成凌亂的傷口。正確使用止血帶會阻止血流。 Xtreme Bleeding Moulages 可與患者模擬器的 STAT 系列一起使...